WAC 296-842-15005
Conduct fit testing
You must
(1) Provide, at no cost to the employee,
fit-tests for all tight fitting respirators on
the following schedule:
(a) Before employees are assigned duties
that may require the use of respirators
(b) At least every 12 months after initial
testing
(c) Whenever any of the following occurs:
• A different respirator facepiece is chosen
such as a different type, model, style, or size
• You become aware of a physical change in an employee that
could affect respirator fit. For example, you may observe, or
be told about, facial scarring, dental changes, cosmetic surgery,
or obvious weight changes
• An employee notifies you, or your LHCP, that the respirator
fit is unacceptable. During the retest, you must give an employee
reasonable opportunity to select a different respirator facepiece
(size, model, etc.).
| 
|
Note:
You may accept a fit-test completed by
a previous employer if:
– You obtain written documentation
of the fit-test
and
– The results of the fit-test aren’t more
than 12 months old
and
– The employee will use the same respirator (the
same type, model, style, and size)
and
– The fit test was conducted in a way that meets
the requirements of WAC 296-842-150
and 296-842-22010.
|
(2) Select and use appropriate fit-testing
procedure from WAC
296-842-22010 of this chapter.
(3) Use quantitative fit-test methods
when a negative pressure respirator will be used in concentrations
requiring a protection factor greater than 10. This includes:
• Full facepiece air-purifying respirators
• SCBAs operated in demand (negative pressure) mode
• Air-line respirators operated in demand mode.
(4) Make sure tight-fitting PAPRs, SCBAs, or air-line respirators are fit tested in negative-pressure mode. This must be done by either:
- (a) Temporarily converting the respirator user's actual facepiece into a negative pressure respirator using the appropriate filters
or
- (b) Using an identical negative pressure air-purifying respirator facepiece as a surrogate for the SCBA, air-line or PAPR. The surrogate facepiece must have the same sealing surfaces as the SCBA, air-line, or PAPR. Remove any modifications made to the respirator facepiece for fit testing and return the facepiece to the NIOSH approved configuration before the facepiece is used in the workplace.
(5) Make sure the person conducting fit
testing is able to do all of the following:
(a) Prepare test solutions if required
(b) Make sure equipment works properly
(c) Perform tests properly
(d) Recognize invalid tests
(e) Calculate fit factors properly if
required.
| 
|
Note:
• No specific training program
or certification is required for those who conduct fit
tests.
• You should consider evaluating
these individuals to determine their proficiency in the
fit-testing method to be used.
• You can use an evaluation form
such as the form included in the American National Standard
for Respirator Fit Testing Methods, ANSI/AIHA Z88.10-2001
to determine if the individual meets these requirements.
Visit www.ansi.org or
www.aiha.org.
|
|